Author: Feng, G.
Paper Title Page
SUPAF02
Beam Alignment Simulation on the Beamline of a Proton Therapy Facility  
 
  • X. Liu, Q.S. Chen, G. Feng, B. Qin
    HUST, Wuhan, People’s Republic of China
 
  Proton therapy is now recognized as one of the most effective radiation therapy methods for cancers. A proton therapy facility with multiple gantry treatment rooms is under development in HUST (Huazhong University of Science and Technology). Misalignments of magnets and beam diagnostics instruments induce the offset of the beam trajectory, which will influence the clinical therapeutic effect. This paper describes the beam alignment simulations based on response matrix and this technology is applied to the design of the HUST-PTF beamline. To perform this study, we use the simulation code ELEGANT, and utilize the global correction method. By optimizing the layout of correctors and beam position monitors, we completed the beam correction calculation. The results show that the accuracy of center beam trajectory in the iso-center is better than 0.5 mm, meeting physical and clinical requirements.  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)